10A AC 전류 감지 센서 모듈, 전류 변압기 전기 과부하/과전류 보호기 자동 메모리 기능

USD 16.84USD 22.46

10A AC 전류 감지 센서 모듈, 전류 변압기 전기 과부하/과전류 보호기 자동 메모리 기능

Description

10A AC Current Detection Sensor Module Current Transformer Electrical Overload/Overcurrent Protector Auto Memory Function

1.Description:

It is a AC Current Detector.The on-off of the relay is controlled by detecting the input voltage and current value through the AC transformer.When the perforation current reaches the preset value,the intelligent start-stop control of the equipment can be realized.

2.Feature:

1).It is suitable for a variety of scenarios to meet the needs of different places.

2).It can be used for motor current monitoring,power distribution cabinet use,equipment current monitoring.

3).It has many different functions to meet the needs of customers.

4).It supports automatic memory function after power failure,and can maintain the function before power failure after power failure.

3.Parameter:

1).Product Name:AC Current Detector

2).Input Voltage:DC 10V-14V

3).Detection Range:AC 220V,0-10A

4).Load Capacity:Control the on-off of the line within DC 30V or within AC 220V 10A.

5).Output Mode:relay switch

6).Accuracy Range:0.01A (Min)

7).Transformer Aperture:5mm

6).Work Temperature:-20℃~50℃

7).Work Humidity:5%~95%RH

8).Size:80*50*18mm

4.Function Introduction:

1).P-1:When the measured current is greater than I1,the relay turns ON;when the measured current is less than I1 again,the relay turns OFF.

2).P-2:When the measured current is less than I1,the relay turns ON;when the measured current is greater than I1,the relay turns OFF.

3).P-3:When the measured current is greater than I2,the relay turns ON;when the measured current is less than I1,the relay turns OFF.

4).P-4:When the measured current is greater than I1,the relay turns ON;it keeps turn ON until the power supply of the circuit board is cut off.

5).P-5:When the measured current is less than I1,the relay turns ON;when the measured current is greater than I2,the relay turns OFF.

6).P-6:When the measured current is less than I1,the relay turns ON;it keeps turning ON until the power supply of the circuit board is cut off.

7).P-7:When the measured current is between I1 and I2,the relay turns ON,and in other cases,the relay turns OFF.

8).P-8:When the measured current is between I1 and I2,the relay turns ON;it keeps turn ON until the power supply of the circuit board is cut off.

9).P-9:When the measured current is less than I1 or greater than I2,the relay is turned ON,and in other cases,the relay is turned OFF.

10).P-10:When the measured current is less than I1 or greater than I2,the relay will turn ON;it will keep turning ON until the power supply of the circuit board is cut off.

11).Note:Both I1 and I2 current parameters can be adjusted.

5.Product Setting Instructions:

1).Threshold adjustment:

1.1).Long press S1 to enter the setting:display P -XX,adjust the mode through S2 and S3.

1.2).Short press S1 to display the corresponding mode current threshold:adjust the threshold through S2 and S3.

1.3).After the setting is completed,short press S1 to enter the next threshold or return to the standby interface.

2).Current calibration:

1.1).Long press S3 to enter the current calibration,and adjust the actual current value through S1 and S2.

1.2).For example:the actual current value measured by the multimeter is IA,and the display value of the board is deviated.Enter the current calibration and adjust the value to 1.00A.

1.3).Short press S3 to calibrate and save.

3).System reset:

1.1).Long press S2 for five seconds to reset the system,and all data are initialized to the factory state.

6.Usage Scenarios:

1).Motor current detection

2).Use of power distribution cabinet

3).Device current detection

4).Electrical measurement automatic control and scheduling system

Specification

Model Number : AC Current Detection Sensor

Type : Logic ICs

Operating Temperature : -20~50 Celsius

Condition : New

is_customized : Yes

Brand Name : IS

Application : Electric Toy

Package : SOP

Origin : Mainland China

Supply Voltage : DC 10V-14V

Accuracy Range : 0.01A (Min)

Output Mode : Relay Switch

Load Capacity : Control the on-off of the line within DC 30V or within AC 220V 5A

Feature : AC Current Detection Sensor

Input Voltage : DC 10V-14V

Detection Range : AC 220V, 0-10A

Transformer Aperture : 5mm

1-200PCS
USD 1.37
+