Humidity/Temperature Transmitter Sht20 Sensor Module Precision Temperature and Humidity Monitoring Industrial Modbus RS485

USD 3.69USD 4.61

Humidity/Temperature Transmitter Sht20 Sensor Module Precision Temperature and Humidity Monitoring Industrial Modbus RS485

Description

Humidity/Temperature Transmitter Sht20 Sensor Module Precision Temperature and Humidity Monitoring Industrial Modbus RS485

 

 

Product description:

        the product adopts industrial chip, imported with high precision SHT20 the temperature and humidity sensor ensures the excellent reliability, high precision and interchangeability of the product. Using RS485 the hardware interface (with lightning protection design ), the protocol layer is compatible with the standard industry Modbus-Rtu protocol. The present set of products MODBUS the protocol is integrated with the common protocol. Users can choose the communication protocol by themselves. The common protocol has the automatic upload function ( connection RS485 the temperature and humidity will be automatically output through the serial port adjustment tool).

Product Highlights:

industrial products, high progress SHT20 the temperature and humidity sensor, RS485 communication;

standard MODBUS the protocol is integrated with the common protocol, and users can choose the communication protocol by themselves;

baud rate can be set by itself;

common protocols have automatic upload function, and the upload rate can be set by yourself. 

Product parameters:

working voltage: DC4-30V(The maximum limit their statements to no more33V)

maximum power:0.2W

operating temperature: temperature-20+60 humidity0%RH-100%RH

control accuracy: temperature± 0.3(25) humidity±3%RH(25)

output interface: RS485 communication (standard MODBUS protocol and custom common protocol), see The Protocol Description

address: you can set1-247 the default value is1

baud rate: the default9600(Users can set it by themselves),8 bit Data,1 bit stop, no verification

size:60*30*18

 

 

products used in the function code:

0 x03: read holding registers

0 x04:  read input registers

0 x06: write a single holding register

0 x10: write multiple hold registers

register type

register Address

the data content

the number of bytes

 

the input register

0x0001

the temperature value

2

0x0002

humidity value

2

 

 

the holding register

0x0101

device address

(1~247 (in Chinese))

2

0x0102

the baud rate

0:9600

1:14400

2:19200

2

0x0103

temperature correction(/10)

-10.0-10.0

2

0x0104

humidity correction value(/10)

-10.0-10.0

2

 

 

Modbus  communication Format:

the host sends a data frame:

the slave address

function Code

register Address

the high byte

register Address

the low byte

number of registers

the high byte

number of registers

the low byte

CRC

the high byte

CRC

the low byte

 

 

 

 

 

 

 

 

slave response data frame:

the slave address

in response to the function code

the number of bytes

register1 data

the high byte

register1 data

the low byte

register N data

the high byte

register N data

the low byte

CRC

the high byte

CRC

the low byte

 

 

 

 

 

 

 

 

 

  MODBUS the command frame

host reads temperature command frames(0 x04) :

the slave address

function Code

register Address

the high byte

register Address

the low byte

number of registers

the high byte

number of registers

the low byte

CRC

the high byte

CRC

the low byte

0x01

0x04

0x00

0x01

0x00

0x01

0x60

0x0a

slave response data frame:

the slave address

function Code

the number of bytes

temperature

the high byte

temperature

the low byte

CRC

the high byte

CRC

the low byte

0x01

0x04

0x02

0x01

0x31

0x79

0x74

 

the temperature value= 0 x131, to decimal conversion305 actual temperature value = 305 / 10=30.5 

note: temperature is marked16 decimal number, temperature value= 0 xFF33, to decimal conversion -205 the actual temperature= -20.5 ℃;

 

host reads humidity command frames(0 x04) :

the slave address

function Code

register Address

the high byte

register Address

the low byte

number of registers

the high byte

number of registers

the low byte

CRC

the high byte

CRC

the low byte

0x01

0x04

0x00

0x02

0x00

0x01

0xC1

0xCA

slave response data frame:

the slave address

function Code

the number of bytes

humidity

the high byte

humidity

the low byte

CRC

the high byte

CRC

the low byte

0x01

0x04

0x02

0x02

0x22

0xD1

0xBA

humidity value= 0 x222, to decimal conversion546 actual humidity value= 546 / 10 = 54.6% ;

 

continuously read temperature and humidity command frames(0 x04) :

the slave address

function Code

register Address

the high byte

register Address

the low byte

number of registers

the high byte

number of registers

the low byte

CRC

the high byte

CRC

the low byte

0x01

0x04

0x00

0x01

0x00

0x02

0x20

0x0B

slave response data frame:

the slave address

function Code

the number of bytes

temperature

the high byte

temperature

the low byte

humidity

the high byte

humidity

the low byte

CRC

the high byte

CRC

the low byte

0x01

0x04

0x04

0x01

0x31

0x02

0x22

0x2A

0xCE

 

read the content of the maintenance register(0 x03) :

take reading the slave address as an example:

the slave address

function Code

register Address

the high byte

register Address

the low byte

number of registers

the high byte

number of registers

the low byte

CRC

the high byte

CRC

the low byte

0x01

0x03

0x01

0x01

0x00

0x01

0xD4

0x0F

slave response frame:

the slave address

function Code

the number of bytes

the slave address

the high byte

the slave address

the low byte

CRC

the high byte

CRC

the low byte

0x01

0x03

0x02

0x00

0x01

0x30

0x18

 

modify the content of the maintenance register(0 x06) :

take modifying the slave address as an example:

the slave address

function Code

register Address

the high byte

register Address

the low byte

the register value

the high byte

the register value

the low byte

CRC

the high byte

CRC

the low byte

0x01

0x06

0x01

0x01

0x00

0x08

0xD4

0x0F

modify the slave address: 0x08=8

 

the slave response frame( and send the same):

the slave address

function Code

register Address

the high byte

register Address

the low byte

the register value

the high byte

the register value

the low byte

CRC

the high byte

CRC

the low byte

0x01

0x06

0x01

0x01

0x00

0x08

0xD4

0x0F

 

continuous modify holding register(0 x10) :

the slave address

function Code

the start address

the high byte

the start address

the low byte

number of registers

the high byte

number of registers

the low byte

the number of bytes

register1 the high byte

register1 the low byte

register2 the high byte

register2 the low byte

CRC

the high byte

CRC

the low byte

0x01

0x06

0x01

0x01

0x00

0x02

0x04

0x00

0x20

0x25

0x80

0x25

0x09

modify the slave address: 0x20=32

the baud rate: 0x2580=9600

slave response frame:

the slave address

function Code

register Address

the high byte

register Address

the low byte

number of registers

the high byte

number of registers

the low byte

CRC

the high byte

CRC

the low byte

0x01

0x06

0x00

0x11

0x00

0x04

0xD4

0x0F

 

 

                    the ordinary version protocol

the baud rate of the default 9600(Users can set it by themselves), 8bit Data, 1bit stop, no verification

RS485 communication

 

serial commands

description

READ

trigger a temperature and humidity report

(27.467.7%  temperature27.4℃ humidity67.7%)

AUTO

start the automatic report function of temperature and humidity

( ditto)

STOP

stop Automatic temperature and humidity reporting function

BR:XXXX

set the baud rate

from 9600 to 19200

(BR:9600  the baud rate9600)

TC:XX.X

set the temperature correction

(-10.0~10.0)

(TC:02.0 temperature correction2.0)

HC:XX.X

setting the humidity calibration

(-10.0~10.0)

(HC:-05.1  humidity correction value is-5.1%)

HZ:XXX

set the temperature and humidity report rate

(0.5,1,2,5,10)

(HZ:2  not only automatically reported rate 2)

PARAM

read the current system settings

 

 

PARAM instructions:

TC:0.0,HC:0.0,BR:9600,HZ:1-> temperature correction0.0 humidity correction value0.0 the baud rate9600 report rate 1Hz

SLAVE_ADD:1  -> MODBUS the slave address 0x01

Specification